We basically manufacture below range of products. 

  • High voltage breakdown tester (also called as Hipot test kit/Insulation breakdown tester)
  • Custom made electrical and electronics products, test jigs, process control products etc. 

Please check the below for various High voltage breakdown testers manufactured and supplied to our customers 


Cauvery systems manufactures high voltage breakdown tester which is useful for checking breakdown (FLASH /OVER) voltage of insulation materials, Electrical and Electronics components, Coils, Transformers, Chokes, Switches, Connectors, Plastics, Rubber ETC.

Automatic tripping facility is being provided in our instruments when the leakage current exceeds the tripping level set by front panel control.

 MAINS ON / H T ON / H T OFF / TEST FAIL& TEST PASS - Visual Indication 

Optional :

*  Special rating / Designers of H V Tester, as per customer Requirements.

*  Audio Buzzer provided while H T ON or TEST FAIL

* Calibration Certificate shall be supplied along with H V Tester (From any Lab / Institution accredited by M/s. NABL / ETDC - Bangalore)

*  H T & Ground Output cable Fixed or Removable (1 meter)

* Voltage - Increase / Decrease by Push Button control (Motorized unit)      

TECHNICAL SPECIFICATIONS:-

H T  VOLTAGE:     3, 5, 10, 20, 30, 50…… k V    AC / DC 

SET CURRENT:     3-30, 5-50, 10-100, 30-300, 50-500, 60-600….....mA. (Leakage Current variable)  

STAGE INDICATION: MOVING COIL TYPE   PANEL METERS / DIGITAL TYPE (Optional) 

FOR VOLTAGE & LEAKAGE CURRENT  

ACCURACY OF READING:   + / - 5 % (Full scale reading) for Voltage & + / - 3 % Leakage Current on No load condition Only.  

POWER   REQUIREMENTS:   230 VOLTS  + / - 10%  50 Hz, 1 Ph 

SAFETY PRECAUTION      :  HIGH VOLTAGE Appears in output / Test terminals, Only when the H T ON Button is pressed. 

CONTROLS AND INDICATIONS 

INDICATIONS:MAINS ON,  H T  ON,  H T  OFF,TEST  PASS & TEST  FAIL.  

MAINS ON SWITCH: Energizes the instruments in ON position-  MAINS ON   

VARIABLE VOLTAGE KNOB:Control to vary the Output voltage at the Test Terminals (Auto Transformer Knob) 

LEAKAGE CURRENT SET:  Control to set the required leakage current  

METERS: Digital Panel Meter to indicate the output Voltage & Current reading at the Test Terminals.  

RED LAMP: Indicates High Voltage is OFF in the output Test Terminals - H T OFF  

GREEN LAMP -1:   Indicates presence of high voltage in the Test Terminals - H T ON   

GREEN LAMP – 2:  Indicates Device Under Test is with stood the Set High voltage after the set time elapsed - TEST PASS  

AMBER / YELLOW LAMP:  IndicatesDevice Under Testis unable to withstand the Set High voltage 

(Test Fail / Insulation breakdown)- TEST FAIL  

GREEN PUSH BUTTON1:  Enables high voltage at the Test leads - H T ON  

GREEN PUSH BUTTON2 :  Enables Timer starts to count down after the required T

Test high voltage set- TIMER ON 

RED PUSH BUTTON: Disables high voltage at the Test –RESET 

 

 